logo

Environment-friendly Novec1230 Fire Suppression System Without Residue For Battery Room

1セット
MOQ
交渉可能
価格
Environment-friendly Novec1230 Fire Suppression System Without Residue For Battery Room
特徴 ギャラリー 製品の説明 見積依頼
特徴
仕様
ストレージ圧力: 4.2MPA
噴霧する時間: ≤10s
密度 を 満たす: ≤1420kg/m3
公称圧力: 5.3Mpa
テスト圧力: 8.4MPa
作業力: DC 24V 1.6A
作業温度: 0℃~50℃
保護された地帯の範囲:: 割合:≤800mの² 容積:≤3600mの³
起動モード: 自動の、電気マニュアル、機械マニュアル
シリンダーボリューム: 40L、70Lの、100Lの、120Lの、150Lの、180L
ハイライト:

0℃~50℃ Working Temperature Novec 1230 Fire Suppression System

,

≤800m² Protected Zone Clean Agent Fire Suppression System

,

40L-180L Cylinder Volume Novec1230 Fire Suppression System

基本情報
起源の場所: 中国
ブランド名: Air Giant
証明: CAL,CMA,CNAS,ILAC-MRA,CCC
モデル番号: QMP40/4.2、QMP70/4.2、QMP100/4.2、QMP120/4.2、QMP150/4.2、QMP180/4.2
お支払配送条件
パッケージの詳細: バブルバッグまたは紙の付いた合板の外側の箱
受渡し時間: 10〜15営業日
支払条件: L/C、D/P、T/T、Western Union、PayPal、クレジットカード
供給の能力: 1週あたりの28000セット
製品の説明

Environment-friendly Novec1230 Fire Suppression System Without Residue For Battery Room

 

Description


The molecular formula of perfluorohexanone Novec1230 is CE3CF2C (O) CF (CE3) 2, and the relative molecular weight is 316.04. It is a clear, colorless, slightly odorous, and easily gasified liquid fire extinguishing agent at room temperature, which is not a dry hazardous substance and does not leave residue after release. The fire extinguishing agent is neither dry HFC nor inert gas. It is a new halon substitute and has made breakthrough progress in halon substitute field.

 

Novec1230 gas fire extinguishing agent does not contain bromine and chlorine elements, and does not damage the body oxygen layer after fire extinguishing, and its body oxygen consumption potential value is zero. At the same time, more importantly, unlike hydrofluorocarbon fire extinguishing agent, Novec1230 has a very low greenhouse effect potential value, GWP=1 is equivalent to CO2, and Novec1230 has a short life in the atmosphere, only 3-5 days, so it fundamentally solves the environmental pollution caused by halon fire extinguishing agent and hydrofluorocarbon fire extinguishing agent.

 

Novec1230 is environmentally friendly, safe for personnel, non-conductive, does not leave residue after fire extinguishing, does not damage equipment, and has excellent fire extinguishing performance. Therefore, it is a green environmental protection fire extinguishing agent designated by its name and its application range is wide.

 

Working Principle
 

Here is the illustration of working principle to whole system.


 
Environment-friendly Novec1230 Fire Suppression System Without Residue For Battery Room 0

 
 
Application
 

As its name says, the single zone pipe network Novec1230 fire suppression system is suitable for a single protected zone, whose volume should be less than 3600 cubic meters as well as proportion should be less than 800 square meters. Because of its property and principles of putting off fire, the single zone pipe network Novec1230 fire suppression system can be used to protect some large and also significant places, such as the followings:

 

- Computer rooms

 

- Telecommunication center

 

- Facilities underground

 

- Offshore oil extraction

 

- Library

 

- Data and paper archives

 

- Valuable article storage

 

- Power generator storage room


Environment-friendly Novec1230 Fire Suppression System Without Residue For Battery Room 1

 
Advantages


It is very efficient for you to protect your possession. Since it is a system, it includes extinguishing device to put out fire in a short time. It means all agent will be discharged in less than 10 seconds. Then it will be flooding overall. In addition, it has time-delay mechanism. It is around 2 minutes. It means when a fire happens, there is enough time for people escaping the building. We have listed out two points for customer as reference.

1. Flexible application in protection zones. As its structure and assembly of other useful components, it can concentrate one very big protection zone with the combination of multiple storage cylinders. Its coverage can be also very small with the system of a single cylinde.

2. Combined distribution system. The most distinctive and flexible advantage of this system is combined distribution system, which will combine multiple rooms in one district or building but with different dimensions or in different floor. Meanwhile, it can reduce the cost based on the original by the least and safe utilization of fire extinguishing gas. Because of the adoption of selective valves that can guide the fire extinguishing gas into the room on fire, so it would be relatively smarter to monitor each room to avoid an accident. It is worthy to mention that the combined rooms should be less than 8 including 8 in accordance with our standard.

 


 
Packages
 

We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.
 
Environment-friendly Novec1230 Fire Suppression System Without Residue For Battery Room 2